Dryblock Calibrators

Series TECAL
  • Entry for thermostat test
  • UPI for an automatically loop calibration of sensors
  • stationary and mobile applicable
  • odorless operation
  • maintenance-free
  • more riskless handling as fluidised baths
  • quick reaktion during temperature cycles
  • bronze- or aluminium core also with multiple borings
  • Software and sensor interface for a fully automatic calibration

 

Temperaturkalibrator
Techne Tecal with CalSoft

type min. temp. [°C] max. temp. [°C] temp. stability [°C] accuracy [°C] Datasheets
 
 140S - 40 + 140 ±0,05 ± 0,3 PDF
 140H - 40 + 140 ±0,05 ± 0,3
 425S + 40 + 425 ±0,05 ± 0,3 PDF
 425H + 40 + 425 ±0,05 ± 0,3
 650S + 45 + 650 ±0,09 ± 0,4 PDF
 650H + 45 + 650 ±0,09 ± 0,4
140F - 40 + 140 ±0,05 ± 0,3 PDF
425F + 40 + 425 ±0,05 ± 0,3
650F + 45 + 650 ±0,09 ± 0,4
700X + 45 + 700 ±0,03 ± 0,25 PDF
1200S + 150 + 1200 ±3 ± 0,2 PDF


Optional accessory:

Calsoft Software for a PC supported calibration incl. RS232 cabel
CH 5 external chiller for TECAL 140, Tecal 140F and 650F
  carrying bag, suitcase, calibrator certificate


only for Tecal H series:

UPI User Probe Interface

The UPI enables sensors to calibrate without any operator interaction by "Closed Loop Calibration" connection direct to the calibrator.


CH-5 Kühler / Chiller

Technical Data
The CH-5 Chiller Unit is designed for use in conjunction with the TECAL 140 Calibrators to achieve calibration temperatures down to -40°C.

In normal ambient temperatures of up to 20°C the minimum temperature obtainable with the TECAL models 140 is 45°C below ambient; by artificially cooling the heatsink of the units with water from the chiller -40°C can be obtained.

The unit is designed to run on distilled or deionised water. The CH-5 can also be used to pass cooling water through the cooling coil on the Calibration Baths (LCB) and Cooling Probe (FDBOOCP) minimum temperature +10°C.

A Refrigeration Control Pack (FCPID) can be supplied fitted to any Techne Refrigerated Bath. The Control Pack will turn the Refrigeration unit "On" or "off" when required following a signal from the TU-20D/TU-20HT thermoregulator when used in conjunction with Thermsoft software.
Working temperature range 4°C to 15°C
Cooling capacity 400W
Temperature control Thermostat on/off
Electrical control Manual
Length 430mm
Width 235mm
Height (including pump) 524mm
BATH OPENING:
Length 300mm
Width 140mm
Bath Depth 150mm
Bath Capacity 5 litres
Pump Capacity 20 litres/minute
Net Weight 26.5kg

Technical Data    UPI
 
probe type resolution accuracy range Metallblockkalibrator
Techne Tecal with UPI interface
K t/c 0.1°C ±0.5°C or 0.3% -50 to 650°C
J t/c 0.1°C ±0.5°C or 0.3% -50 to 650°C
N t/c 0.1°C ±0.5°C or 0.3% -50 to 650°C
T t/c 0.1°C ±0.5°C or 0.3% -50 to 400°C
E t/c 0.1°C ±0.5°C or 0.3% -50 to 650°C
100 Ohm

RTD

0.1°C ±0.3°C or 0.1% -50 to 650°C
1000 Ohm RTD 0.1°C ±0.3°C or 0.1% -50 to 650°C
0-10 mA 1.0uA ±2.0uA or
±0.002mA
0 to 10mA
10.1 to 20 mA 1.0uA ±2.0uA or
±0.002mA
10.1 to 20mA